Standard Probes
|
Part # |
Type of Tip |
Processing Volume |
Tip Diameter |
Intensity |
Amplitude (microns) |
| 200 |
Replaceable Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
| 201 |
Solid Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
| 201S |
Sapphire Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
|
| 207 |
Replaceable Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
| 208 |
Solid Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
| 208S |
Sapphire Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
|
| 209 |
Solid Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
| 209S |
Sapphire Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
| 210 |
Replaceable Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
|
Standard #200 Probe
|
Replacement Tips for Standard Probes
|
| Part # |
Tip Diameter |
For Use With |
| 406 |
1/2" (12.7 mm) |
#200 |
| 407 |
3/4" (19.1 mm) |
#207 |
| 408 |
1" (25.4 mm) |
#210 |
|
|
Detached Replaceable Tip
|
|
New vs. Old
|
|
Microtips attach to the standard (#200) probe, except (#420) Stepped Microtip which attaches directly to the converter.
**The (#420) Stepped Microtip has two sections: The upper section (#421) and lower (#422).
|
Microtip Probes
|
Part # |
Processing Volume |
Tip Diameter |
Intensity |
Amplitude (microns) |
| 418 |
0.2-5 ml |
1/16" (1.6 mm) |
Ultra High |
320 µm |
| 419 |
0.5-15 ml |
1/8" (3.2 mm) |
Ultra High |
240 µm |
| 419A |
2-25 ml |
3/16" (4.8 mm) |
Very High |
150 µm |
| 419B |
5-50 ml |
1/4" (6.4 mm) |
High |
115 µm |
| 420** |
0.5-15 ml |
1/8" (3.2 mm) |
Very High |
205 µm |
|
|
Microtip
|
|
High intensity probes are used instead of standard probes and offer double the amplitude of a standard probe.
|
High Intensity Probes
|
Part # |
Type of Tip |
Processing Volume |
Tip Diameter |
Intensity |
Amplitude (microns) |
| 305 |
Replaceable Tip |
25-500 ml |
3/4" (19.1 mm) |
High |
120 µm |
| 306 |
Solid Tip |
25-500 ml |
3/4" (19.1 mm) |
High |
120 µm |
| 310 |
Solid Tip |
50-1,000 ml |
1" (25.4 mm) |
Medium |
60 µm |
| 311 |
Replaceable Tip |
50-1,000 ml |
1" (25.4 mm) |
Medium |
60 µm |
|
|
High Intensity Probe
|
|
Standard probes may not be long enough to fit down into long necked vessels. Extenders are available in 5" and 10" lengths.
Extenders are attached to standard probes with replaceable tips of the same diameter.
|
Probe Extenders
|
Part # |
Type of Tip |
Processing Volume |
Tip Diameter |
Intensity |
Amplitude (microns) |
| 406HW |
Solid Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
| 406HWT |
Replaceable Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
| 406HWS |
Sapphire Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
|
| 407HW |
Solid Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
| 407HWT |
Replaceable Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
| 407HWS |
Sapphire Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
|
| 408HW |
Solid Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
| 408HWT |
Replaceable Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
|
| 406FW |
Solid Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
| 406FWT |
Replaceable Tip |
10-250 ml |
1/2" (12.7 mm) |
High |
120 µm |
|
| 407FW |
Solid Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
| 407FWT |
Replaceable Tip |
25-500 ml |
3/4" (19.1 mm) |
Medium |
60 µm |
|
| 408FW |
Solid Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
| 408FWT |
Replaceable Tip |
50-1,000 ml |
1" (25.4 mm) |
Low |
30 µm |
|
|
Probe Extender
|
|
Boosters will increase the intensity of standard probes. Boosters attach between the converter and standard probe to increase amplitude by the gain ratio indicated below.
|
Booster Probes
|
| Part # |
For Use With |
Gain Ratio |
| 328A |
3/4" and 1" probes |
2 to 1 |
| 328B |
3/4" and 1" probes |
2.5 to 1 |
*Amplitude measurement at setting 10 (100%)
|